Custom OEM Energy Meter Manufacturer I Saving

Custom OEM Energy Meter Manufacturer I Saving

We deliver full-spectrum services including smart meters, data terminals, cloud software and system O&M, empowering enterprises and power utilities with reliable energy management systems.

One-Stop Energy Metering & Management Solutions

One-Stop Energy Metering & Management Solutions

Stable wireless communication, compact structure and easy installation. Realize remote meter reading, power consumption monitoring and centralized management for power distribution systems.

Trusted Meter Supplier & Custom OEM Service

Trusted Meter Supplier & Custom OEM Service

Complete product certification, mature supply chain and customized technical support. Long-term partnership for power distributors, engineering contractors and global utility clients.

Company Profiles

Company Profiles

Jiangsu Saving Electronics Co., Ltd. is a one-stop energy metering management service provider with intelligent electricity meters at its core, offering a full range of services including metering equipment, data acquisition devices, cloud software, system integration, and system operation and maintenance. The company always adheres to a technology-centered and market-oriented business policy, advocating the business philosophy of 'co-creation, sharing, mutual progress, and win-win.' Our mission is 'focusing on energy management to assist energy saving and emission reduction,' our vision is 'safer electricity use, more peace of mind for customers, happier employees, and a lower-carbon society,' our commitment is 'accurate metering, reliable and trustworthy,' and our principle is 'honest operation, mutual benefit, and win-win.' Innovation is the eternal pursuit of Senwei people. We will continue to leverage our technological advantages in the field of energy metering management to help customers achieve scientific energy use and the goal of energy saving and consumption reduction, contributing to the creation of a resource-saving and environmentally friendly society.

Jiangsu Saving Electronic Co., Ltd.

Main Product

Power Data Gateway Terminal (4G/LoRa) RTU1218
Power Data Gateway Terminal (4G/LoRa) RTU1218
The power data gateway terminal is primarily designed for electricity consumption monitoring. It features upstream 4G wireless communication capabilities and downstream LoRa wireless meter reading, enabling a fully wireless communication architecture that facilitates electricity monitoring, centralized meter reading, and remote management for users. The product offers numerous advantages, including rapid and stable communication, a compact form factor, and ease of installation. It can be flexibly installed within power distribution cabinets to enable sub-metering, statistical analysis, and monitoring of electrical energy consumption across different zones and load types.
Three-Phase Four-Wire Fee-Control Smart Energy Meter DT/SZY1218-D
Three-Phase Four-Wire Fee-Control Smart Energy Meter DT/SZY1218-D
The Three-Phase Fee-Control Smart Energy Meter is a state-of-the-art instrument designed and manufactured to meet the actual electricity consumption needs of industrial users, utilizing large-scale integrated circuits, digital sampling and processing technologies, and Surface Mount Technology (SMT).
Three-Phase Electronic Energy Meter DTS1218
Three-Phase Electronic Energy Meter DTS1218
The Model DTS1218 Three-Phase Electronic Energy Meter is a state-of-the-art instrument designed and manufactured to meet the actual power consumption requirements of industrial users, utilizing large-scale integrated circuits, digital sampling and processing technology, and SMT processes.
4G Three-Phase DIN-Rail Smart Energy Meter DDSU1218
4G Three-Phase DIN-Rail Smart Energy Meter DDSU1218
The DTSU1218 three-phase DIN-rail energy meter is designed to measure single- and three-phase AC active energy at rated frequencies of 50 Hz and 60 Hz. It features functions such as prepayment, load control, RS485 communication, and 4G communication. Its performance specifications comply with the technical requirements for energy meters stipulated in the national standards GB/T 17215.321-2021 and GB/T 17215.322-2022.
G Type Single-phase Intelligent Energy Meter with Power Control DDZY1218-Z
G Type Single-phase Intelligent Energy Meter with Power Control DDZY1218-Z
The DDZY1218-Z single-phase smart energy meter is a next-generation electricity meter developed by our company in accordance with technical specifications for smart meters established by the State Grid Corporation. Designed to comply with GB/T 17215.321-2021 and DL/T 645-2007 standards, this product utilizes dedicated large-scale integrated circuits and SMT manufacturing processes, featuring comprehensive functions including energy metering, data processing, real-time monitoring, automated control, and information exchange.
Three-phase Four-wire Electronic Energy Meter (Guide Rail) DTSU1218
Three-phase Four-wire Electronic Energy Meter (Guide Rail) DTSU1218
DTSU1218 three-phase four-wire electronic energy meter (guide rail) is a new generation of energy metering products developed and produced by our company in accordance with relevant technical specifications. This product adopts dedicated large-scale integrated circuits and SMT production technology, and has functions such as energy metering, data processing, real-time monitoring, and information interaction. The RS485 communication interface supports Modbus and DL/T 645 dual communication protocols. This product is widely used in various control systems, energy management systems, community power monitoring, industrial automation and other power management automation systems.
OEM&OEM

OEM&OEM

professional

professional

Certification

Certification

quality

quality

New Arrivals

News

CT or Direct Connection? Choosing the Right Energy Meter Input
CT or Direct Connection? Choosing the Right Energy Meter Input Here's a clear guide for specifying CT-operated vs direct-connected energy meters for utility, industrial, and commercial projects: ### CT-operated energy meter (transformer-operated, CT-operated kWh meter) - **Design for high-current circuits**: for loads that exceed the meter's direct-input amperage rating, the line current is stepped down by external current transformers; the meter measures the secondary current (typically 5 A or 1 A). - **Typical current ratings**: the meter's rated input matches the CT secondary (commonly 1 A or 5 A), while the primary circuit can carry hundreds or thousands of amps depending on the CT ratio. - **CT ratio selection**: choose a CT primary rating close to (but above) the maximum expected load current, and match the meter's programmed primary/secondary ratio to the CT ratio (for example, 400/5 A) for correct energy registration. - **Installation**: CT secondary wiring must go to the meter's current terminals, with correct polarity, and CT circuits should not be open-circuited while energized. - **Safety**: CT secondaries can produce dangerous voltages if opened under load; use shorting links before servicing, observe lockout/tagout, and size CTs to the load. - **Bulk specification**: specify secondary current (1 A or 5 A), CT ratio (for example, 400/5 A), accuracy class, and whether the meter is standalone or panel-mounted. - **Cost**: higher total cost than a basic direct-connected meter because CTs, wiring, and installation labor are added, but it is the correct option for high-current feeders. ### Direct-connected energy meter (direct-wire, direct-input kWh meter) - **Design for lower-current circuits**: line current passes directly through the meter's current terminals without external CTs. - **Typical current ratings**: commonly 20 A, 50 A, 100 A (continuous), with voltage options matched to single-phase or three-phase systems. - **CT ratio selection**: not applicable—these meters do not use CTs; sizing is based directly on the maximum line current. - **Installation**: simpler than CT-operated metering: line and load conductors connect directly to the meter terminals. - **Safety**: use proper conductor sizing, torque terminals to specification, and maintain appropriate working clearance; no open-CT hazard. - **Bulk specification**: specify the maximum current rating (for example, 100 A), voltage class, single-phase or three-phase configuration, and panel/socket mount style. - **Cost**: generally lower cost than CT-operated metering for the same voltage class because no CTs are required, but it is limited to lower-current circuits. ### Key selection rules Choose a **direct-connected meter** when the load current is within the meter's rated direct-input range. Choose a **CT-operated meter** when the load is above the direct-connect rating, or when you need standard CT secondary inputs for large feeders. Always match the CT ratio and meter programming, verify polarity, and ensure CT secondaries are never left open while energized.
Guide to Replacing Existing Meters
Guide to Replacing Existing Meters Plan electricity meter replacement with Saving Meter. Review hardware fit, closing readings, data continuity, system migration, and bulk supply requirements.
Energy Metering at EV Charging Stations: A Procurement Guide for Operators
Energy Metering at EV Charging Stations: A Procurement Guide for Operators Compare the plan's AC-side energy metering for EV charging site with Saving Meter across feeder coverage, meter inputs, data connections, and manufacturer support: - **Feeder coverage**: The plan may allocate metering at the service entrance, per circuit breaker, or only at selected charging ports. Saving Meter generally covers individual feeders or circuits. - **Meter inputs**: Confirm whether the plan supports CT, CT/VC, or MBus inputs, split-phase or 3-phase systems, and 100A–200A or higher current ranges. - **Data connections**: Check the connection options: RS-485 Modbus, LTE-M, NB-IoT, LoRaWAN, Ethernet, OCPP integration, or API access. Saving Meter offers multiple outputs. - **Manufacturer support**: Compare warranty length, firmware updates, technical response time, and local support availability. If you'd like, I can create a **side-by-side comparison table** with these dimensions. Would you like me to do that?
View all
Submit information

Submit information