Main function
|
Function name
|
Function description |
Function provide
|
|
Measurement of kWh
|
Total active kWh (positive and negative in total)
|
■ |
|
Measurement ofelectrical parameters
|
U 、I 、P 、Q 、S 、PF、F |
■ |
|
Pre-paid mode
|
prepaid recharge, data encryption
|
■ |
|
Control
|
Built-in high-capacity sub-holding relay toachieve load on-off control
|
■ |
|
LCDdisplay |
8 bits section LCD display
|
■ |
|
Communication
|
Communication interface: RS485, Communication protocol: MODBUS-RTU、DL/T645-2007
|
■ |
|
Multi-tariff
|
5 tariffrates, 14 timeintervalbyday
|
□ |
(■:means standard;□:means optional)
Note: Pre-paid mode function can only be achieved with the pre-paid system which designed by Acrel Co,. Ltd.
Technical parameter
|
Technical parameter
|
DTSU1218 |
|
|
Voltage |
Referencevoltage
|
3×220/380V |
|
Reference frequency
|
50Hz |
|
|
Consumption
|
<4VA(Eachphase) |
|
|
Current
|
Input current
|
0.015-0.075(6)A 0.2-0.5(80)A |
|
Starting current
|
Connect directly: 0.004Ib, connect via CT: 0.002In
|
|
|
Consumption
|
<4VA |
|
| Measurementperformance |
Accuracy of measuring
|
1 Class
|
|
Clock accuracy
|
Error ≤0.5s/d |
|
|
Active pulse
|
Pulse width
|
80ms±20ms |
|
Pulse constant
|
6400imp/kWh, 400 imp/kWh |
|
|
Communication
|
Interface
|
RS485(A+、B-) 4G
|
|
Connection mode
|
Shielded twisted pair conductors
|
|
|
Protocol
|
DL/T 645-2007 |
|
|
Mechanical performance
|
Outline(Length×Width×Height)
|
126*100*75mm |
|
Maximumwiringability (flexible cable)
|
25mm2 |
|
|
Work environment
|
Workt emperature
|
-25℃~55℃ |
|
Storage temperature
|
-40℃~70℃ |
|
|
Relative humidity
|
≤95%(Nocondensation) |
|
|
Altitude
|
<2000m |
|
Functional Description
The functions of this product are categorized into two types: standard core functions and optional extended functions. Standard functions constitute the product's default factory configuration, while optional functions require specific customization prior to ordering. Detailed functional descriptions and application scenarios are outlined below:
Energy Metering Function
• **Metering Range:** Supports bidirectional metering of total active energy in three-phase AC circuits. It accurately measures both forward and reverse active energy, thereby meeting the energy metering requirements for scenarios such as grid-tied PV systems and reactive power compensation.
• **Metering Accuracy:** Achieves Class B accuracy for active energy metering and Class 2 accuracy for reactive energy metering. Characterized by minimal metering error, it complies with national standards for high-precision metering.
• **Pulse Output:** Equipped with an active energy pulse output interface, featuring a pulse width of 80 ms ± 20 ms.
Real-time Electrical Parameter Measurement Function
Enables real-time measurement of key electrical parameters within three-phase AC circuits, providing essential data support for power distribution status monitoring and fault diagnosis. Measured parameters include
Recommended products