4G Three-Phase DIN-Rail Smart Energy Meter DDSU1218
4G Three-Phase DIN-Rail Smart Energy Meter DDSU1218

4G Three-Phase DIN-Rail Smart Energy Meter DDSU1218

Product Introduction

The DTSU1218 three-phase DIN-rail energy meter is designed to measure single- and three-phase AC active energy at rated frequencies of 50 Hz and 60 Hz. It features functions such as prepayment, load control, RS485 communication, and 4G communication. Its performance specifications comply with the technical requirements for energy meters stipulated in the national standards GB/T 17215.321-2021 and GB/T 17215.322-2022.
facebook
line
Whatsapp
Pinterest
Tumblr
Linkedin

Main function

Function name

Function description

Function provide
Measurement of kWh
Total active kWh (positive and negative in total)

■

Measurement ofelectrical parameters

U 、I  、P 、Q 、S 、PF、F

■

Pre-paid mode
prepaid recharge, data encryption

■

Control
Built-in high-capacity sub-holding relay toachieve load on-off control

■

LCDdisplay

8 bits section LCD display

■

Communication
Communication interface: RS485, Communication protocol: MODBUS-RTU、DL/T645-2007

■

Multi-tariff
5 tariffrates, 14 timeintervalbyday

□

 
(■:means standard;□:means optional)
Note: Pre-paid mode function can only be achieved with the pre-paid system which designed by Acrel Co,. Ltd.
 

Technical parameter

Technical parameter

DTSU1218

Voltage

 

Referencevoltage

 

3×220/380V

 

Reference frequency

 

50Hz

Consumption

<4VA(Eachphase)

 

Current

 

Input current

0.015-0.075(6)A    0.2-0.5(80)A

Starting current
Connect directly: 0.004Ib, connect via CT: 0.002In

 

Consumption

 

<4VA

Measurementperformance
Accuracy of measuring
1 Class
Clock accuracy

Error ≤0.5s/d

 

Active pulse

 

Pulse width

80ms±20ms

Pulse constant

6400imp/kWh, 400 imp/kWh

Communication
Interface
RS485(A+、B-) 4G
Connection mode
Shielded twisted pair conductors
Protocol

DL/T 645-2007

Mechanical performance
Outline(Length×Width×Height)

126*100*75mm

Maximumwiringability (flexible cable)

25mm2

Work environment
Workt emperature

-25℃~55℃

Storage temperature

-40℃~70℃

Relative humidity

≤95%(Nocondensation)

Altitude

<2000m

 

Functional Description
The functions of this product are categorized into two types: standard core functions and optional extended functions. Standard functions constitute the product's default factory configuration, while optional functions require specific customization prior to ordering. Detailed functional descriptions and application scenarios are outlined below:
 
Energy Metering Function
•   **Metering Range:** Supports bidirectional metering of total active energy in three-phase AC circuits. It accurately measures both forward and reverse active energy, thereby meeting the energy metering requirements for scenarios such as grid-tied PV systems and reactive power compensation.
•   **Metering Accuracy:** Achieves Class B accuracy for active energy metering and Class 2 accuracy for reactive energy metering. Characterized by minimal metering error, it complies with national standards for high-precision metering.
•   **Pulse Output:** Equipped with an active energy pulse output interface, featuring a pulse width of 80 ms ± 20 ms.
 
Real-time Electrical Parameter Measurement Function
Enables real-time measurement of key electrical parameters within three-phase AC circuits, providing essential data support for power distribution status monitoring and fault diagnosis. Measured parameters include

Recommended products

Recommended products